Deslauriers PCF3048 Plastic Column Form (PCF) for Concrete Forming, 30in Dia X 4ft
- Lightweight
- Reusable
- Stackable
- Waterproof
- Cost Effective
- Saves Time, Money and Labor
- Smooth Surface
- U.V. Resistant
- No Spiral Marks
- Prevents Binding & Sticking
- Easy to strip
FAQ for the Plastic Column Form (PCF)
How high can I pour the Plastic Column Form (PCF) for Concrete Forming? The height is not the issue, but rather how fast should you pour. Deslauriers recommends a pour rate not to exceed 1200psf or an 8 foot liquid head at 70° F.Furthermore, standard practices limit concrete free fall to a max of 5 feet. How many reuses can I get? The actual number of reuses of the PCF is dependent upon various jobsite conditions. Higher liquid head, higher rates of pour, excess vibration, drilling of holes, and rough handling place greater stress on the form. These stresses and the severity of same can result in a detrimental effect upon the reusable life of the form.
Why are there two sets of holes on the vertical flanges of the Plastic Column Form? There were several reasons for this concept. The inner 3 hole pattern allows for a tighter joint for higher pours (4 feet or more). Whereas, the outer 2 hole pattern is sufficient for shorter pours-thus saving on labor. The outer holes, along with the center vertical rib, allow for the attachment of bracing.
Can I cut the Plastic Column Form to a custom size? The Plastic Column Forms can be cut between the double flange at the 4 foot level with a hand saw or a Sawzall and still be utilized back to the 8 foot level. These forms are marked at one foot intervals and can be cut anywhere; however once they are cut other than the 4 foot double flange; they cannot be utilized back to an 8 footer.
Can the Plastic Column Forms be used for a bull-nosed application? No. The pressure exerted by the length in conjunction with rest of the form could cause blow-out to occur. Deslauriers recommends using a steel column form for this purpose.
How do you brace the Plastic Column Form (PCF)? Basically the same as a fiber tube, use a template at the bottom and plumb with a wood 2 x 4 or turnbuckle.
When can you tell if the Plastic Column Form (PCF) is approaching its usable limit? Good indicators are enlargement of bolt holes, any cracks or splits on form body or ribs and any noticeable separation of vertical flanges during a pour. It is important to inspect form for any damage or cracks prior to each use. If unsure, do not use.
Are the horizontal ribs strong enough to use as a ladder? No. The ribs are not designed for this type of point loading. Further, standard safety regulations prohibit this activity. Always use proper ladders as specified by OSHA, ANSI, etc.
Does sunlight affect the Plastic Column Form (PCF)? As with any plastic, long term ultraviolet light exposure breaks down plastic properties. Even with UV inhibitors, this process is merely slowed. Thus, if you expect to store the PCF for a long period of time, placement in the shade, or better yet, covered will protect the plastic from damaging UV.
How's the best way to clean the Plastic Column Form (PCF)? First, a light coat of form release will help prevent concrete buildup. To clean, we suggest muriatic acid or light power wash.
Can power tools be used to tighten bolts? Sure, but carefully. Over-tightening the bolts can cause the bolt head or nut to dig into the flange creating a possible weak spot. When possible hand tighten or use a washer as a backup.
How do you attach the Plastic Column Form (PCF) to a fibre tube? The simplest method is to cut a 3" to 4" section of horizontal flange from the PCF. Use this unit to clamp onto the top of a tube. Bolt a section of PCF to this "clamp" and you have a unit that can be used over and over to secure a PCF to a tube.
Can attachments be nailed to a Plastic Column Form (PCF) or should you first drill a pilot hole? The form may develop a split if attempting just nail, thus drilling is recommended.
What about using an external vibrator on the Plastic Column Form (PCF)? No, this could damage the form. Additionally, care should be taken when using an internal vibrator so that it does not to come in contact with the sides of the form.