Autoclaves

Device Autoclave Testing: Oven Qualifications

Autoclave steam sterilization is done under controlled conditions and environment with thermostatic trap. With the advancement in professional development and contributions within the medical instrumentation field, especially by organizations like Association for the Advancement of Medical Instrumentation (AAMI), there has been significant progress and improvement in standards and practices related to sterilization and medical devices. Monitoring methods used in steam sterilization process are critical. It is important to use chemical indicators, such as the Bowie-Dick Test which serves as a Type 2 chemical indicator, along with other methods like biological indicators and mechanical monitoring to ensure sterilization is achieved effectively and reliably. The process involves exposing items to direct steam at a specific pressure for a specific time. The most common setting for sterilization is 121 degrees Celsius (250 degrees Fahrenheit) at 15 psi for 15 to 20 minutes depending on the load and contents. This method is effective because the moist heat carried by the steam denatures enzymes and structural proteins of microorganisms.

Autoclave Testing

Autoclave testing is a critical component of ensuring the effectiveness of the sterilization process in health care facilities. Autoclaves, also known as steam sterilizers, use high-pressure steam to kill bacterial spores and other microorganisms on medical instrumentation. To verify the efficacy of the sterilization process, various tests are performed, including the Bowie-Dick test, vacuum leak test, and biological indicators. These tests help to ensure that the autoclave is functioning properly and that the sterilization process is achieving the desired level of sterility assurance.

Types of Testing

There are several types of autoclave tests that can be performed, including chemical indicators, biological indicators, and process challenge devices. Chemical indicators, such as test strips, are used to verify that the autoclave has reached the proper usage and that the sterilizing agent has penetrated the load. Biological indicators, such as spore tests, are used to demonstrate that the autoclave is capable of killing bacterial spores. Process challenge devices, such as the Bowie-Dick test pack, are used to simulate the sterilization of complex instrumentation and to verify that the autoclave is functioning properly. Vacuum leak tests are also performed to ensure that the autoclave chamber is properly sealed and that air is being removed during the sterilization cycle.

Autoclave Parts and Controls

Sterilization: Where items are placed for sterilization. Small tabletop units to large industrial autoclaves. For effective sterilization tests, place test packs above the drain as this is the coldest point in the chamber and can affect the process. Operators are not to use prevacuum cycle if the sterilizer unit does not pass the Bowie-Dick Test, operators are monitored during testing to ensure effective sterilization. The Bowie-Dick test pack, often a small, disposable pack made of thermochromic paper and porous materials, is essential for determining proper air removal and ensuring effective sterilization during the autoclaving process.

Steam Generator: Produces steam that is injected into the chamber. Some autoclaves have built-in generator while others require external steam source.

Controls: Modern autoclaves have electronic controls that allow precise control of temperature, pressure and time. These systems have safety features to prevent operation under unsafe conditions.

Vacuum System: Used in pre-vacuum autoclaves to remove air from the chamber and ensure even steam penetration especially for sterilizing porous items or materials in packs.

Safety Valves and Locks: Prevents the autoclave door from being opened while the chamber is pressurized thus preventing accidents.

Testing

Laboratories: Used in laboratory settings for sterilizing lab tools, especially in microbiology where culture media and instruments must be kept sterile to avoid cross-contamination.

Industrial Applications: Used for curing composites and in the manufacturing of high-strength materials that require concrete curing exposure to high pressure.

Biological Indicators

Regular Maintenance: Check and maintain the autoclave regularly to ensure safe and efficient operation. Keeping the equipment in service is critical for compliance with safety standards and preventing breaches in sterilization protocols.

Qualification

Ensuring the efficacy of steam sterilization is critical and this is done through a rigorous qualification and validation. This trial is divided into four parts: design qualification, installation qualification, operational qualification and performance qualification.

Design Qualification (DQ): This initial phase verifies that it meets the required specifications and industry standards. It involves a thorough review of the design to ensure it can achieve the desired outcomes.

Installation Qualification (IQ): Once the design is approved, the next step is to confirm that it is properly installed according to the manufacturer’s requirements. This includes checking that all components are correctly positioned and connected, ensuring the system is ready for operation.

Operational Qualification (OQ): This phase involves the device to ensure it performs as intended. It includes verifying that the control system, sensors and monitoring systems function correctly and meet the required specifications. Throughout the validation of the tool must be calibrated regularly to ensure accuracy and reliability. This involves checking and adjusting the control systems, sensors and monitoring systems to operate precisely. Detailed documentation of each step is critical to meet industry standards and regulations. This documentation should include the lot number for each product to ensure traceability and quality assurance. This documentation not only records the equipment’s performance but also helps to identify potential issues that may arise over time.

Re-validation is necessary to ensure ongoing compliance and to address any changes in the device or validation. By following these installation qualification and operational qualification of validation procedures, including the verification of spore and Bowie-Dick tests, the workplace can ensure it operates safely and effectively and gives reliable results.

Design and Selection

A robust control system is essential for monitoring and controlling, pressure and other critical parameters. This system should have sensors and monitoring systems to provide accurate and reliable data and the device should operate within the required specifications. Easy calibration and maintenance is also important design consideration as it ensures it remains accurate and reliable over time.

Proper tracking and monitoring and the use of lights are essential to ensure safe and effective devices, thereby enhancing infection control. Chemical indicators within the devices provide immediate proof of successful results, with a color change indicating microbial growth after incubation.

It is important for the operational integrity and performance using Bowie-Dick test and Verify Process Challenge Devices to ensure it is working properly. A frequently used sterilizer requires daily checks with lights to quickly identify malfunctions or procedural errors, a proactive approach for assurance.

Challenges and Considerations

Maintenance: Regular maintenance is key the devices working correctly and consistently. This includes checking seals, filters and mechanical parts.

Training and Operation: Proper training for medical staff on using them is important to avoid operator error that can lead to failure. Using wrong cycle parameters or wrong packaging can affect results, resulting to positive spore results. Understanding spore procedures is important as a ‘fail’ can occur if the spores in the vial survive, meaning failure or if both control vials show no activity, which is also considered as ‘fail’.

[]