Vaccine Monitoring and Control Solutions Data Logger Kit, Docking Station, NIST
FEATURES:
-
Data Logging – Records time and temperature data for later download
-
Day alarm summary – Displays in calendar-like format alarms for the last 30 days
-
Current time & temperature – Shows the current time and temperature when not in review mode
-
Push Button Logging start with optional delayed start or specific Time & Date start
-
Rapid Download! Takes only seconds to download recordings
-
‘Pre-Start’ logging – LogTag® can be configured to record even if it has not been started.
-
High performance at low cost
-
Thin flat case – Fits easily into packaging and thin enough to be easily mailed “letter rate”.
-
Real time clock records time & temperature simultaneously
-
Easy to use LogTag Analyzer software that runs on any PC configures LogTag® for recording then downloads resulting data for analysis. Data can also be exported to formats compatible with other applications such as Excel
-
Re-calibration to achieve higher accuracy possible. The VFC400 allows you to calibrate the device in place, providing convenience and ensuring regulatory compliance.
-
Control Solutions can also offer expedited calibration services for urgent requirements.
-
Each VFC400 kit is shipped as a complete item, ready for immediate use.
-
You can add the VFC400 to your cart for easy purchasing.
-
You can review all products in your cart before checkout.
-
You can add the VFC400 to your wish list or product list for future reference or bulk ordering.
-
For more information, instructional and calibration videos are available.
SPECIFICATIONS:
ACCURACY ±0.3 Deg C from +40 to -40°C. For more information about the Non-Mercury Glass Thermometer, 0 to 230F, Total Immersion, see our guide. For more information on how to convert 450°F to Celsius, see our guide.
ALARMING Audible and visual alarm for out of range temperatures.
BATTERY LIFE 1 year. NOTE: 6 minute logging, day statistics reviewed on the display no more than once daily for no longer than 30 seconds each time. Download data monthly. NOTE: Continual activation of the audible alarm will reduce the working life of the battery. When an alarm is triggered, the alarm should be cleared and reset as soon as possible.
Vaccine Monitoring
Vaccine monitoring is crucial for the safety and effectiveness of vaccines, especially within programs like the Vaccines for Children (VFC) initiative. To comply with VFC requirements, healthcare providers must use a vaccine monitoring data logger that continuously tracks storage temperatures and ensures vaccines remain viable. A data logger is the backbone of any vaccine management system, providing real-time insights and alerts to prevent temperature excursions. Control Solutions, a VFC compliance partner, offers advanced solutions that use smart probe technology to deliver accurate, reliable monitoring. By choosing a data logger from a VFC compliance partner, clinics and healthcare facilities can be confident in their compliance and vaccine inventory.
Product Overview: VFC400 Data Logger Kit and Docking Station
The VFC400 Data Logger Kit from Control Solutions is a complete, easy to use vaccine storage monitoring solution. This kit includes a high accuracy data logger, smart probe and docking station to monitor storage systems and keep supplies safe. The VFC400 kit is VFC compliant so healthcare providers can meet all storage regulations. With smart probe technology, the kit eliminates the guesswork and manual checks for storage conditions in refrigerators and freezers. The docking station simplifies data transfer and analysis for compliance and vaccine supply protection.
Calibration and NIST Accreditation
Calibration is critical for any vaccine monitoring data logger and Control Solutions is a leader in this area. As an ISO/IEC 17025:2017 accredited calibration lab, Control Solutions offers world class calibration services that meet the highest industry standards. Their 2017 accredited calibration lab ensures every data logger is precisely calibrated so healthcare providers can trust their monitoring systems. With expedited calibration and technology to recalibrate in place, Control Solutions eliminates downtime and maintains continuous compliance. As a VFC compliance partner, Control Solutions provides solutions that meet all regulatory requirements, they are the trusted choice for healthcare facilities nationwide.
Specifications
The VFC400 Data Logger Kit and Docking Station has many features to make it perfect for storage monitoring. The data logger has an audible alarm that alerts staff to any temperature deviations that could compromise safety. Smart probe technology gives highly accurate temperature readings so both refrigerators and freezers are monitored with precision. The docking station has quick and easy data transfer for efficient analysis and reporting. The VFC400 kit is compatible with multiple storage systems so you have a reliable and effective way to monitor and protect your vaccine inventory.