Pressure Chamber for Concrete Air Meter
In a Type B meter, the pressure chamber stores a known air charge that is released into the sealed concrete sample; the resulting pressure drop gives the air content. A dented or leaking chamber skews every reading, so this replacement keeps an existing pressure air meter in service.
- Test methods: ASTM C231, AASHTO T 152
- Use: replacement chamber for Type B concrete air meters
Seal it with a new pressure chamber cap if the old cap threads are worn.