Fast
Shipping
Quick,
Simple Ordering
Clear,
Upfront Pricing
Over 30,000
Happy Customers
Exceptional
Customer Service
Industry's Largest
Catalog
Dry Ice Temperature Sensor: Ultra-Low Temp Data Logger with Probe
The LTTREL8 Low Temperature Remote Probe Logger measures and stores up to 8000 temperature readings over -80°C to +40°C (-112°F to +104°F) measurement range from associated interchangeable LogTag® ST10 type remote probe temperature sensor (available in lengths up to 3 meters (9’10”).
It is intended for use in monitoring of articles stored at low temperatures such as in dry ice type environments. The logger is ideal for transit monitoring of shipments that use dry ice cooling agents in packaging to maintain required temperatures.
LTTREL8 is easily configured for recording conditions including delayed start, interval, number of readings and configuration of conditions to activate the ALERT indicator.
FEATURES:
-
Up to 8,000 recordings – enough for the longest trip.
-
In-transit inspections can be recorded at the push of a button.
-
Users can press the button to mark events or pauses during monitoring.
-
Comprehensive customization options including alarm settings, interval and trip duration.
-
A real time clock provides date/ time stamps for each reading.
-
Push-to-start button with optional delay or a specific time & date.
-
Suitable for use inside packaging that contains dry ice cooling agents, ensuring accurate temperature monitoring during transit.
-
Stores comprehensive information, including device status, configuration, and recorded data, which can be accessed and reviewed using the companion software.
SPECIFICATIONS:
Product Model LTTREL8
External Sensor Measurement Range
-80°C to +40°C (-112°F to +104°F).
Operating Range
-20°C to +40°C (-4°F to +104°F).
Storage
-10°C to +55°C (14°F to +131°F)
Reading Accuracy
-
Better than ±1°C (±1.8°F) for -30°C to +20°C (-22°F to +68°F).
-
Better than ±1.2°C (±2.1°F) for -45°C to -30°C (-49°F to -22°F)
-
and +20°C to +40°C (+68°F to +104°F).
-
Better than ±1.7°C (±3.1°F) for -80°C to -45°C (-112°F to -49°F).
-
Actual performance is typically much better than the rated values.
-
Accuracy figures can be improved by recalibration.
-
Reading Resolution
-
Less than 0.1°C (0.2°F) for -80°C to 0.0°C (-112°F to +32°F),
-
Less than 0.2°C (0.4°F) for 0.0°C to +20°C (+32°F to +68°F),
-
Less than 0.5°C (0.9°F) for +20°C to +40°C (+68°F to +104°F)
-
LogTag Analyzer® currently displays to one decimal place of °C or °F.
-
The native resolution is what is stored in the LogTag®.
Sensor Reaction Time
Typically less than 2 minutes(T90) in moving air (1m/s) for ST10S type
Recording Capacity
-
8,031 temperature readings. 53 days @ 10min logging, 80 days @ 15min logging.
-
Sampling Interval
-
Configurable from 30 seconds to several hours. For more information on devices with these features, such as the Sper Infrared Thermometer Gun, see the best indoor outdoor thermometers.
Logging Start Options
Push button start with optional start delay or specific date & time.
Recording Indication
Flashing ‘OK’ indicator / flashing ‘ALERT’ indicator. The logger provides immediate visual access to alert and status indicators, so users do not require access to a PC or software to check the device status during transit.
Download Time Typically less than 5 seconds for full memory (8031 readings), depending on computer or readout device used. The logger features USB connectivity for quick data transfer and compatibility with most PCs.
Configuration and data download are managed via PC. LogTag's freely available companion software, LogTag Analyzer, allows users to configure the logger, read and analyze recorded data, and export information for compliance or review. This companion software LogTag Analyzer supports charting, exporting, and setting alerts, making it essential for transit monitoring and cold chain compliance.
Environmental IP61.
Power Source CR2450 3V LiMnO2 Battery (Fixed).
Battery Life 1 year storage, followed by 2 – 3 years of normal use
-
(based on 15 minute logging, download data monthly).
-
Real Time Clock
-
Built-in real time clock.
-
Rated accuracy ±25ppm @ 25°C (equivalent to 2.5 seconds/day).
-
Rated coefficient is -0.034 ±0.006ppm/°C (I.e typically +/- 0.00294 seconds/day/°C).
Standard Remote Probe Cable Lengths
Standard: 0.5m (19”). Extended: 3m (9’10”) (recommended maximum).
Remote Probe Cable Type PTFE (FDA food contact rated) coaxial.
Size 86mm (3.39″)H x 54.5mm (2.15″)W x 8.6mm(0.34″)T.
Weight 34g (1.2 oz)
Case Material Polycarbonate.
Introduction to Dry Ice Monitoring
Monitoring in dry ice environments is a vital process for industries such as pharmaceuticals, food, and logistics, where maintaining strict control is essential for product safety and quality. Dry ice, as a powerful cooling agent, is commonly used to keep sensitive products at ultra-low temperatures during storage and transportation. However, the effectiveness of dry ice depends on precise temperature monitoring throughout the entire process.
Dry ice data loggers are specifically designed to operate in temperature environments ranging from -80°C to +40°C (-112°F to +104°F), making them ideal for dry ice shipments and other ultra-low temperature applications. These devices provide immediate visual confirmation of conditions, allowing users to quickly assess whether products have remained within safe limits. With features such as easily configured settings, delayed start options, customizable intervals, and clear alarm status indicators, these data loggers streamline the temperature monitoring process. Companion software, like LogTag Analyzer, further enhances usability by enabling users to configure devices, download data, and analyze readings efficiently. This combination of advanced technology and user-friendly design ensures that products remain protected throughout their journey in challenging temperature environments.
Key Features of the Device
A dry ice temperature data logger stands out for its high accuracy and robust performance in low conditions. One of its most notable features is the ability to provide immediate indication of status through visual alerts. The red alert indicator instantly notifies users if any readings fall outside the configured limits, while the green OK indicator offers visual confirmation that the unit is operating within the desired range. This immediate feedback is crucial for maintaining the integrity of sensitive shipments.
Data Logger Specifications
The dry ice temperature data logger is engineered to deliver reliable performance in demanding conditions. It operates across -90℃ to 70℃, ensuring suitability for both ultra-low and moderately cold environments. With an impressive accuracy of ±0.5℃ and a fine resolution of 0.1℃, the device provides precise readings essential for sensitive applications.
The logger’s memory can store up to 35,000 readings, supporting frequent temperature sampling intervals and long-term monitoring. Users can configure the device to start logging at a specific time, with a flexible interval that can be set anywhere from 1 minute to 24 hours, depending on the requirements of the shipment or storage process. Powered by a 3.6V Lithium battery, the data logger offers up to 120 days of operation, making it ideal for extended transportation or storage periods. Compliance with CE, RoHS, and EN12830 standards ensures the device meets industry regulations for cold chain monitoring, providing peace of mind for users in regulated industries.
Applications and Benefits
Data loggers are indispensable tools for a variety of industries that require strict control, such as pharmaceuticals, food, and logistics. These devices are particularly beneficial for monitoring shipments, where maintaining low temps is critical to preserving product quality and safety. The ability to set frequent temperature sampling intervals allows for detailed tracking of fluctuations, ensuring that any deviations are quickly detected and addressed.
Immediate visual confirmation of conditions, provided by the logger’s alert indicators, enables users to take prompt action if it move outside acceptable areas. This feature is especially valuable during transportation, where quick decisions can prevent product loss. The logger’s suitability for low applications makes it ideal for monitoring frozen food, vaccines, and other sensitive products during storage and transit. Its robust design and configurable settings ensure reliable performance in a wide area of conditions, from sea and air freight to distribution centers and cold storage facilities. By providing accurate, real-time monitoring and comprehensive records, these loggers help companies comply with industry standards, protect valuable shipments, and maintain the highest levels of product integrity.