CRYO TEMP Ultra-Low Temperature Data Logger, As Low As -86C
Ultra Low Temperature Data Logger, records temperatures as low as –86°C. Stand-alone device does not require any additional probes.
FEATURES:
- Ultra Low Operating Temperature (-86°C)
- May Be Placed In Direct Contact With Dry Ice
- No External Probes Or Wiring
- Programmable Alarm & Warn Ranges w/Alarm Delay
- Led Status Indicators For Instant Alarm Notification
- High Accuracy
- Magnetic Start
- Optional Password Protection
- Splash Resistant (Ip64)
- CE Compliant
SPECIFICATIONS:
Temperature Sensor: NTC Thermistor
Temperature Range: -86°C to +35°C recommended, may be used up to +55°C
Temperature Resolution: 0.1°C
Calibrated Accuracy: ±1.0°C
Memory: 32,767 readings; software configurable memory wrap
Reading Rate: 5 seconds to 30 minutes, selectable in software
Start Modes: Software programmable immediate start, delay start up to 30 days in advance or manual start with magnetic switch
Temperature Alarm: Software programmable high and low alarm limits, high and low warn limits each setpoint may be individually enabled or disabled
Alarm Delay: Software programmable time delay for warn/alarm limits. Logger will not indicate out of range status until the temperature has been out of range for a for a set period of time.
Status Indicators:
Green- Blinks to indicate safe conditions during logging
Yellow- Blinks to indicate warn limits have been exceeded
Red- Blinks to indicate alarm criteria (limits/delay) have been exceeded
Password Protection:
An optional password may be programmed into the device to restrict access to configuration options. Data may be read out without the password.
Calibration: Digital calibration through software
Calibration Date: Automatically recorded within device
Battery Type: 3.6V lithium battery (LTC-7PN), factory replaceable only
Battery Life: 2 years typical @ 25°C, 1 min. reading intervals 1 year typical @ –80°C, 1 min. reading intervals
Data Format: Date and time stamped ºC, ºF, K, ºR
Time Accuracy: ±2 minutes/month max. at 20 to 30°C ±5 minutes/month max at –80°C
Computer Interface: USB docking station to PC (IFC300) 38,400 baud
Software: XP SP3/Vista/Windows 7
Operating Environment: -86°C to +35°C (may be used up to +55°C); 0 to 100% RH
Dimensions: 3.3” x 2.1” x 0.4” (83 mm x 54 mm x 11 mm)
Ingress Protection/IP: IP65 (splash resistant, not submersible)
Enclosure: ABS plastic, white, polycarbonate labeling